jiloerotic.blogg.se

Abbott istat manual
Abbott istat manual












abbott istat manual
  1. ABBOTT ISTAT MANUAL SERIAL
  2. ABBOTT ISTAT MANUAL UPDATE
  3. ABBOTT ISTAT MANUAL PORTABLE
  4. ABBOTT ISTAT MANUAL SOFTWARE
  5. ABBOTT ISTAT MANUAL SIMULATOR

It also makes it easy for healthcare providers to understand results, fast. Provides on-screen guidance during testingĪnd identifies problems and potential solutions in real time From the color of the touchscreen, to the durable design, every aspect of the system lets the user have more, better control. See, we told you it was easy! It was designed to be.

ABBOTT ISTAT MANUAL SOFTWARE

Step 4: Upload information automatically into the LIS/HIS through the Data Management Software Step 3: View the results on the handheld screen within minutes. Step 2: Close the cartridge and insert into the i-STAT handheld. Step 1: Insert two or three drops of blood into the cartridge. Testing can be performed at the patient’s side, with only 2-3 drops of whole blood. Note: Do not connect the BAM until instructed to do so by the JammLite program.The Abbot i-STAT 1 system is so easy to use, we only had to write four steps down.

ABBOTT ISTAT MANUAL UPDATE

  • If using a Central Data Station Version 5 or another computer, connect the BAM to a 9 pin COM port using the D-Connector and Mini Din Connector from an i-STAT Software Update Kit.
  • If using a Central Data Station Version 4, connect the BAM to COM5 on the back of the CDS using a Modular Data Cable (i-STAT grey flat cable with RJ45 connectors).
  • COM5 is first port from the inside on the lower row.
  • If using a Central Data Station Version 4 with quad cards: Connect the IR Link to COM5 on the back of the CDS using a Modular Data Cable (i-STAT grey flat cable with RJ45 connectors).
  • If using a Central Data Station Version 5, a Central Data Station Version 4 with digiboard, or any other computer using Windows 95 or above, connect the IR Link to a 9 pin COM port using an i-STAT Software Update Kit as illustrated below.
  • Click off the checkmark in the box beside Enable Customization at the top left of the window.Įxit the CDS and all other open programs. Click on Administration in the main menu bar.ģ. Click Yes to the confirmation messages and the Utility will close.ġ. Click on the i-STAT Analyzer Customization Profile Utility icon or access by clicking Programs and i-STAT CDS.Ģ. The main menu bar, then click on About.ġ. If you are not sure which CDS you have, click Help on To disable customization differ for the Central Data Station Version 4 and Centralĭata Station Version 5. If you are not sure if Customization is disabled, follow the steps below. If you use Central Data Station Version 5 and your CDS is on Version 5.18a or If you do not use Customization or Customization is disabled, skip this step. For the software update, the battery voltage should be well above theħ.5 V point at which the low battery message is displayed.
  • Test records will not be erased if only the CLEW software is updated.Ĭheck Battery Voltage: Analyzers consume power during the software up-ĭate.
  • The Product Update lists the software that is to be updated.
  • There are two types of software in the analyzers: application (JAMS).
  • Not erased from the i-STAT1 Analyzer (series 300).

    ABBOTT ISTAT MANUAL PORTABLE

    To the Central Data Station (CDS) program or ensure that all test records haveīeen transcribed before updating a Portable Clinical Analyzer. (series 200) when the application software is updated.

    abbott istat manual abbott istat manual

    Save Data: All test records are erased in the i-STAT Portable Clinical Analyzer Save Stored Results & Check Battery Voltage

    ABBOTT ISTAT MANUAL SERIAL

    * It is not neccessary to connect a serial Downloader if using network protocol to update i-STAT 1 Analyzer.

    ABBOTT ISTAT MANUAL SIMULATOR

    Insert an Electronic Simulator into each updated analyzer Re-start the CDS, update CLEW, re-eanable Customization Select the local port or select TCP\IP and enter the IP addressĬlick on Update and follow the directions on the screenĬlick on Exit or X in upper right corner of screen Select the instrument (analyzer) type to be updated Transfer the files from the JAMS disk to the computer Save the data on Portable Clinical Analyzersĭisable Customization on the Central Data StationĬonnect an IR Link or Downloader* to the computer If you just need reminders, follow the Summary of the Procedure. If this is the first time you are updating your analyzer, follow the Detailed Procedure. An i-STAT/DE server is not recommended for use with this utility. An i-STAT Central Data Station Version 5 or a Point of Care Central Workstation meet this requirement and can be used. To use this utility, you must have a computer with Windows ® 95 or higher. The JammLite procedure is simple with just one screen for all analyzer types and software versions. The JammLite Utility must be used to update software in the i-STAT ®1 Analyzer and can be used to update the i-STAT Portable Clinical Analyzer and the Blood Analysis Module.














    Abbott istat manual